Hydraulic jacks for lifting and erecting welded as well as bolted storage tanks are manufactured and exported by Bygging since the last 33 years. Bygging's jacks have been used at installations for Shell, BP, Vopak, Oiltanking, Exxon Mobil, Chevron, Pertamina, KOC, KNPC, Aramco, VTTI.

Jack capacities : 12 ton, 18 ton and 25 ton

The heaviest tank erected using Bygging jacking equipment weighed 1900 tons.

Tanks with floating roofs, column supported roofs, and fixed CS as well as aluminium dome roofs have been erected using Bygging Jacking system.
Yes! I am Interested

Telescopic Jacks for Erecting Bolted Tanks

REQUEST CALLBACK

Telescopic Jacks for Erecting Bolted Tanks
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
BrandBygging

Telescopic jacks manufactured by Bygging are used for building :

  • Bolted tanks
  • Grain storage silos
  • Weded tanks with diamter less than 6 meters

Specifications:


  • Capacity: 3.5 ton and 5.5 ton
  • maximum lift : 2438 mm
Yes! I am Interested

Double Acting Tank Lifting Jack

REQUEST CALLBACK

Double Acting Tank Lifting Jack
  • Double Acting Tank Lifting Jack
  • Double Acting Tank Lifting Jack
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
BrandBygging

These jacks come with a “lifting hook” instead of the lifting arm. The hook holds and lifts the tank shell from the bottom edge of the plate. Welding of lifting lugs and fend-off lugs is eliminated and so is the need to test and repair tank shell plates after removing the lugs.

Procedure for fixing next shell course and removal of hooks is explained below :

The tank is lowered down using jacks, to sit on newly erected shell ring leaving root gap as required. To do this, the jacks are lowered down by about 70 mm. At this time the lifting hooks will not lower down along with jacks, since their downward movement is obstructed by the new shell ring. Now one by one, using a crow bar, the shell plate (which is held by the lifting hook) is wedged towards the front (towards inside of the tank) so as to free the lifting hook and allowing the hook to drop onto the jack.

Tanks with shell plates upto 30 mm thick can be erected using this type of equipment.

Jacking equipment with lifting hook is denoted by the “H” in the Model code.

Yes! I am Interested

Tank Repairs

REQUEST CALLBACK

Tank Repairs
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Buying Jacking equipment is used in the following cases of tank repair :

  • Replacing tank bottom plates and / or annular plates
  • Replacing cathodic protection
  • Repairs to tank foundation in case of foundation settlement
  • Correcting tilt in tank as a result of foundation settlement
  • Replacement of lower most shell course
  • Addition of extra shell course / s to an existing tank

The following services are provided :


  • Provision of jacking equipment and jacking specialist
  • Preparation of Jacking layout including suggesting suitable measures to ensure equal distribution of load from jacks to the ground
  • Preparation of stability calculation

 

Yes! I am Interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Bygging Infrastructure Pvt. Ltd.
Dipak Modi (Director)
69, R.N.A. Arcade, 1st Floor, Lokhandwala Complex Andheri West,
Mumbai - 400053, Maharashtra, India